[email protected] +86 130 3760 0603 Erqi District, Zhengzhou, Henan, China
XBOILER

Bag Filter vs Multi-Tube Dust Collector for Coal Boilers

XBOILER COMPANY industrial boiler
Bag Filter vs Multi-Tube Dust Collector for Coal Boilers

Particulate control on a coal boiler is usually decided by the emission limit, but the choice between a bag filter and a multi-tube collector also changes operating cost, water use and the maintenance routine. Both types are still installed in China; the difference is where each one is appropriate.

How a multi-tube collector works

A multi-tube collector is a cluster of small cyclones inside one casing. Flue gas enters tangentially, spins, and throws particles to the wall, where they fall into a hopper. Each tube is 150-250 mm in diameter, and a 10 t/h boiler may have 40-80 tubes. Pressure drop is 600-900 Pa, there are no consumables, and the device tolerates 400°C without complaint.

Collection efficiency is 80-90% for particles above 10 micrometres, falling to 50-60% for the 2-5 micrometre fraction that carries much of the mass from a spreader-stoker fire. Outlet concentration from a 3 g/Nm3 inlet typically lands at 300-500 mg/Nm3. That fails the 30 mg/Nm3 limit applied to coal boilers in most Chinese provinces and is far from the 10-20 mg/Nm3 ultra-low targets in key regions.

How a bag filter works

Fabric filtration passes gas through a woven or felted medium at 0.8-1.2 m/min air-to-cloth ratio. Dust builds a cake on the surface, and the cake does most of the filtering. Pulse-jet cleaning releases it into the hopper every few minutes to a few hours. Efficiencies of 99.5-99.9% are routine, with outlets of 10-30 mg/Nm3 and 5-10 mg/Nm3 on good media.

The constraint is temperature. Polypropylene bags are limited to about 90°C, polyester to 130°C, PPS to 170-190°C, and glass or PTFE media to 250-260°C. A coal boiler with an economiser usually leaves at 140-160°C, which suits PPS but not polyester; a boiler without an economiser at 200°C needs glass media or a gas cooler.

Sizing follows gas volume, not boiler capacity. A 10 t/h boiler at 1.6 excess air ratio moves roughly 30,000 Nm3/h at 150°C, which calls for about 450 m2 of cloth at 1.1 m/min. Add 15% for air in-leakage and 10% for bag ageing, and the figure becomes 570 m2. A unit quoted at 300 m2 for that duty is priced for the tender, not for compliance.

Side-by-side comparison

Parameter Multi-tube collector Bag filter
Efficiency 80-90% 99.5-99.9%
Outlet from 3 g/Nm3 inlet 300-500 mg/Nm3 10-30 mg/Nm3
Pressure drop 600-900 Pa 1,200-1,800 Pa
Temperature limit no practical limit 90-260°C by media
Consumables none bags every 2-4 years
Compressed air none 0.3-0.6 Nm3/min per 1,000 m2 cloth
Footprint for 10 t/h small, about 2.5 x 2.5 m large, about 6 x 4 m plus hopper
Capital cost, 10 t/h low 2.5-4 times higher

Where each still makes sense

Multi-tube collectors remain common as pre-collectors ahead of a bag filter, where they remove 80-90% of the load and extend bag life, and on small boilers below 2 t/h in regions where the limit is still 80-100 mg/Nm3. They are also the pragmatic choice where flue gas is above 300°C and cooling is not available.

For any boiler above 4 t/h subject to a 30 mg/Nm3 limit, a bag filter is the only compliant option. The additional fan power for 1,200-1,800 Pa is roughly 3-6 kW on a 10 t/h unit, which is small against the cost of a non-compliant stack.

Wear is the multi-tube weakness. The first tube rows take the full abrasive load; coal with 25% ash and hard quartz can wear through 6 mm plate in three to five years. Replacement inserts cost far less than a bag house, which is why some plants keep the cyclone as a wear item where the limit allows it.

Practical selection notes

Hopper design decides whether either device works. A 60 degree hopper with vibrators and a rotary valve beats a 55 degree hopper with a manual slide gate; dust that bridges in the hopper re-enters the gas stream, and the outlet concentration rises with no visible fault.

  • Size the bag filter on actual gas volume at working temperature, including 10-15% air in-leakage.
  • Keep the inlet below the media limit with a 15-20°C margin; a single upset above the limit glazes PPS bags permanently.
  • Use a spark arrestor or cyclone ahead of the bag house on grate-fired coal, because burning char carries over and perforates bags.
  • Provide hopper heaters and insulation where flue gas can drop below the acid dew point at part load.
  • Plan bag replacement as an operating cost over 2-4 years, not as a capital item.

XBOILER COMPANY sizes the dust train from a measured or guaranteed inlet load. A bag filter selected from the boiler rating alone is usually undersized once the real coal ash and excess air are known.

Bagikan: WhatsApp Facebook
WhatsApp’ta sohbet edin
WhatsApp Email Talep