Deaerator Selection: Sizing, Pressure and Oxygen Removal

XBOILER COMPANY industrial boiler
Deaerator Selection: Sizing, Pressure and Oxygen Removal

Oxygen removal is the cheapest corrosion protection in a steam plant. At 0.02 mg/L a deaerator cuts the pitting rate in feed lines and shells to a fraction of what cold, saturated water causes, and it does so using steam the plant already produces. Selection comes down to three decisions: type, pressure and storage volume, in that order.

Why 105 °C is the usual target

Oxygen solubility falls towards zero as water approaches saturation. At 1.2 bar absolute water boils at 105 °C, and the solubility of oxygen drops below 0.02 mg/L while the released gas is vented. This is why pressurised deaerators run at 0.2 to 0.5 bar(g) rather than at atmospheric pressure: the slight positive pressure keeps air out, raises the temperature above 100 °C, and provides net positive suction head for the feed pumps. A tank vented to atmosphere simply cannot reach the same result, however much steam is injected.

Types and where each fits

Type Outlet oxygen Temperature Typical use
Spray 0.03-0.05 mg/L 102-105 °C Shell boilers, 2-10 t/h
Tray 0.02-0.03 mg/L 102-105 °C Steady loads, 5-30 t/h
Spray-tray 0.01-0.02 mg/L 105 °C Most industrial steam plants
Vacuum 0.02-0.05 mg/L 60-80 °C Low-pressure and hot water systems
High pressure below 0.01 mg/L 130-150 °C Boilers above 25 bar

Spray units are compact and cheap but sensitive to load swings. Tray units give better contact and steadier results. The spray-tray combination is what most industrial plants should specify: a spray section for quick heating and a tray stack for the final few parts per million. Vacuum deaerators suit systems that cannot accept 105 °C water, such as some hot water circuits and buildings with low-temperature distribution.

Sizing the storage section

Two numbers are needed: maximum feedwater flow and storage volume. Flow equals maximum evaporation plus blowdown plus any attemperating water, with a 10 percent allowance. Storage is normally 10 to 20 minutes of that flow for process plants and 5 to 10 minutes where load is stable and controls are good. A 10 t/h boiler at 10 percent blowdown needs 11 m3/h; 15 minutes of storage gives 2.75 m3, so a 3 m3 storage section is selected. Do not size on average load: a plant with three batch processes can swing from 3 to 9 t/h within minutes, and a small head will trip the low-level interlock every time the largest vessel starts.

Pressure selection and steam consumption

Heating water from 20 to 105 °C takes about 355 kJ/kg, which is 0.13 kg of steam per kg of water at 8 bar, or roughly 5 to 8 percent of boiler output when the deaerator runs on live steam. Flash steam from blowdown or turbine exhaust can cover most of that. Higher deaerator pressure raises the temperature and cuts oxygen further, but it also raises the feedwater temperature at the economizer inlet, which can reduce economizer duty; the two must be balanced, not optimised separately. The vent must stay open. A deaerator with a closed vent cannot remove oxygen, and the continuous vent loss of 0.5 to 1 percent of steam flow is a deliberate operating cost.

Faults that look like deaerator problems

Most oxygen excursions trace back to something outside the vessel. A failed spray nozzle gives poor distribution and a wet steam space. A sticking level control admits cold make-up in slugs, which cools the storage section below saturation and lets oxygen back into solution. A undersized vent, or one closed by an operator to stop the visible plume, prevents gas release entirely. Pump cavitation that appears as a deaerator fault is often a suction line with an air leak or a strainer partly blocked. Checking these four items before reopening the unit resolves a surprising share of complaints.

Layout and materials

  • Mount the deaerator 3 to 5 m above the feed pump suction to guarantee NPSH
  • Use stainless trays and internals; carbon steel corrodes quickly in the spray zone
  • Fit three-element level control (level, steam flow, feedwater flow) above 10 t/h
  • Sample after the storage section, not at the inlet, or the reading will flatter the unit
  • Insulate head and storage tank; a bare tank can lose a third of the heat just added

XBOILER COMPANY supplies deaerators with spray-tray internals, stainless trays and packaged controls, sized from the boiler rating and the load profile. Our engineers normally specify 15 minutes of storage for process plants and check the NPSH margin against the selected feed pump curve before the order is placed, which is where most site problems with deaerators actually begin.