Capacity: 15~160×104Kcal/h Pressure: 0.8-1.1MPa Fuel: Soft Coal, Anthracite, Bituminous Coal, Lignite, Poor Coal, etc. Application: Food Plant, Chemical Plant, Textile Mill, Plastic Products Factory, Pharmaceutical Factory, Rubber Processing Plant, Petroleum Industry...
- Capacidad y combustible adaptados a su proceso
- Documentación de exportación y soporte de puesta en marcha
- Repuestos y servicio posventa
Especificación
| Capacity | 15~160×104Kcal/h |
|---|---|
| Pressure | 0.8-1.1MPa |
| Fuel | Soft Coal, Anthracite, Bituminous Coal, Lignite, Poor Coal, etc. |
| Application | Food Plant, Chemical Plant, Textile Mill, Plastic Products Factory, Pharmaceutical Factory, Rubber Processing Plant, Petroleum Industry... |
| Efficiency | ≥ 92–98% depending on fuel, model and load |
| Control | PLC / automatic; remote monitoring optional |
| Documentation | General arrangement drawing, material certificates, O&M manual |
| Lead time | 20–45 days after drawing approval |
| Warranty | 12–60 months depending on scope |
Las especificaciones se pueden personalizar. Contáctenos para datos técnicos completos y planos.
Aplicaciones
- Industria alimentaria y de bebidas
- Plantas de aceite de palma y procesamiento de biomasa
- Textil, caucho y plásticos
- Química, farmacéutica y papel
Descripción
XBOILER Product Advantages
![]() |
Thermal Oil Boiler Coil Pipe The heating surface of the boiler body adopts a densely arranged coil structure, consisting of multiple layers of inner, middle, and outer circular coils. The flue gas follows an S-shaped flow path, enabling multi-pass heat transfer with a high heat transfer coefficient and exceptional thermal efficiency. |
![]() |
Boiler Coal Feeder The boiler is equipped with a new-type coal feeder that automatically supplies fuel into the furnace, ensuring uninterrupted coal delivery. With automated coal feeding and slag removal, labor intensity is significantly reduced, leading to lower labor costs for enterprises. |
![]() |
Grate Independent Air ChamberThe grate of the thermal oil boiler features an independent air chamber design, allowing for individual adjustment of airflow. This promotes more complete coal combustion, eliminates black smoke emissions, enhances environmental performance, and reduces fuel costs. |
![]() |
Thermal Oil Boiler Air Preheater A high-efficiency air preheater is installed at the boiler tail to recover waste heat from the flue gas. It preheats the incoming air, reducing flue gas temperature and minimizing heat loss, thereby further improving the overall thermal efficiency of the boiler. |
![]() |
Valves and Instruments The boiler is delivered as a fast-assembled unit, shortening the installation period. It is equipped with high-quality specialized valves and instruments designed for thermal oil boilers, offering excellent sealing performance, accurate measurement, reliable operation, and a long service life. |
Technical Parameters
Find the capacity of the coal fired steam boiler you want and check other parameters of the boiler as a reference.
| Item/Type | Coal Fired Thermal Oil Boiler | ||||||||||
| Rated thermal power | kw | 180 | 300 | 350 | 460 | 700 | 1000 | 1200 | 1400 | 1600 | 1900 |
| ×104 (kcal/h) | 15 | 25 | 30 | 40 | 60 | 80 | 80 | 120 | 140 | 160 | |
| Boiler thermal efficiency % | 73 | 73 | 73 | 73 | 76 | 76 | 76 | 76 | 78 | 78 | |
| Design pressure MPa | 1.1 | ||||||||||
| Max. working temperature ℃ | 320 | ||||||||||
| Medium circulation flow m3/h | 12.5 | 40 | 40 | 60 | 80 | 100 | 100 | 100 | 100 | 160 | |
| Main pipe diameter DN | 40 | 80 | 80 | 100 | 100 | 125 | 125 | 125 | 125 | 150 | |
| Installation capacity kW | 8.5 | 15 | 18/15 | 24/20 | 28/25 | 45/40 | 53/48 | 60/55 | 60 | 80/73 | |
| Fuel type | Bituminous Coal, Soft Coal, Anthracite, Lignite, Poor Coal, etc. | ||||||||||
Document Supply
| No. | Item | Example/Issuer | Qty | Unit |
| 1 | Boiler Drawings | General Drawing, Boiler Proper Drawing, PID (Pipes, Instruments & Valves) Drawing, Foundation Drawing, Boiler Room Design Drawing. | 1 | Set |
| 2 | Boiler Quality Certificate | Issued by the boiler inspection department of China government. | 1 | Set |
| 3 | Certificate of Origin | Such as CO, Form E, Form F, Form A, etc. | 1 | Set |
| 4 | Boiler Thermodynamic Calculation Book | Issued by the boiler supplier. | 1 | Set |
| 5 | Boiler Strength Calculation Book | Issued by the boiler supplier. | 1 | Set |
| 6 | Installation & Operation Instruction | Issued by the boiler supplier. | 1 | Set |
Compared with other options
Typical differences between XBOILER equipment and a general-market alternative.
| Feature | XBOILER | General market |
|---|---|---|
| Build & inspection | Zhengzhou boiler manufacturing base, third-party inspection on every unit | Pure trading company, no engineering team |
| Efficiency on site | Optimised combustion, low excess air, tested at commissioning | Nameplate figure only |
| Documentation | Drawings, material certificates, O&M manual | Limited or on request |
| After-sales | Spare parts and engineer support, remote diagnosis | Varies, often no local stock |
| Customisation | Fuel, pressure, voltage and layout adapted | Fixed catalogue models |
Further reading
Preguntas
¿Se puede personalizar la capacidad?
Sí. La capacidad, la presión y el combustible se ajustan a los requisitos de su proceso.
¿Cuál es el plazo de entrega?
Normalmente de 30 a 60 días hábiles tras la aprobación de los planos.
¿La instalación está incluida?
Ofrecemos supervisión de instalación, puesta en marcha y formación de operadores.
Solicitar cotización
Envíenos sus datos y nuestro equipo técnico preparará una propuesta según sus requisitos.