[email protected] +86 130 3760 0603 Erqi District, Zhengzhou, Henan, China
XBOILER

Chain Grate vs Fixed Grate Coal Boiler: Which Fits Your Plant

XBOILER COMPANY industrial boiler
Chain Grate vs Fixed Grate Coal Boiler: Which Fits Your Plant

Grate choice fixes a coal boiler’s fuel bill, its maintenance pattern and the size of its dust collector for the next fifteen years. Chain grate stokers and fixed grate stokers both burn bituminous coal, yet they behave very differently once coal quality begins to drift. The comparison below is written for plant engineers replacing or adding a boiler in the 2-35 t/h range.

The mechanical difference that drives everything

On a chain grate the fuel bed rests on an endless linked chain that moves slowly from the front hopper to the rear ash dam. Coal is fed by a gate or a spreader, ignites in the first 1.5-2.5 m of travel, and burns out before the chain turns over the discharge. Typical bed thickness is 100-180 mm and chain speed 2-12 m/h, which gives a residence time of roughly 12-25 minutes. Because the bed moves as a solid slab, the fire is stable and the ash leaves dry and granular.

A fixed grate keeps the fuel on stationary or reciprocating bars. A ram or screw pushes fresh coal onto the bed, and the ash is raked or tipped off by moving bars. The fuel does not travel as a continuous slab, so the bed is disturbed several times during combustion. That disturbance helps with caking coals, but it also lifts more fly ash into the furnace and makes the fire less uniform across the width.

Fuel sizing and moisture tolerance

Chain grates want sized coal: 6-25 mm, with less than 30% below 6 mm. Fines below 3 mm fall through the chain or burn in suspension above the bed, which raises dust loading and carbon loss. Lumps above 40 mm give uneven ignition and can damage the chain at the feed end.

Fixed grates are more forgiving on sizing, accepting 0-30 mm with a high fines fraction, but they are less tolerant of moisture. Wet coal on a fixed grate forms a sticky mass that the ram cannot distribute, and the fire develops holes. Chain grates handle 12-18% surface moisture better because the bed is turned over mechanically at the discharge end.

Capacity, turndown and load response

Parameter Chain grate Fixed grate
Typical capacity 2-75 t/h 0.5-20 t/h
Coal size 6-25 mm, low fines 0-30 mm tolerant
Turndown 3:1 to 4:1 1.5:1 to 2:1
Load change rate 5-10% per minute 3-5% per minute
Ash discharge continuous, dry intermittent, manual
Grate drive variable speed motor hydraulic ram or crank

The turndown figure matters more than the nameplate. A chain grate at 25% load still holds a continuous bed and stable ignition; a fixed grate at 25% load tends to develop cold patches and needs auxiliary fuel or intermittent operation. If the plant runs two shifts and idles overnight, that difference decides whether the boiler stays alive.

Efficiency, carbon loss and maintenance

Well-run chain grate boilers reach 78-83% thermal efficiency on coal of 18-21 MJ/kg. The dominant losses are dry flue gas at 8-12%, unburnt carbon in slag and fly ash at 2-6%, and radiation at 1-2%. Fixed grate units typically sit 2-4 points lower, because the disturbed bed throws more fines out of the furnace and the ash pit carries more carbon.

Maintenance is where the two diverge sharply. A chain grate needs chain tension checks monthly, link replacement every 3-5 years, and careful control of clinker so the chain does not overheat. A fixed grate needs bar replacement, ram seal packing and manual ash handling, but its capital cost is 15-25% lower for the same capacity.

What it means for the dust collector

Because a fixed grate entrains more fines, the dust collector behind it must be sized for a higher inlet load: often 3-5 g/Nm3 against 2-3 g/Nm3 from a chain grate. That usually pushes the design from a multi-tube collector to a bag filter, which changes both capital cost and footprint. XBOILER COMPANY sizes the dust train from the expected inlet load rather than from the boiler rating, because the two do not track each other.

Selection rules that hold up in practice

  • Above 10 t/h, chain grate is almost always the right answer: better turndown, continuous ash removal, lower carbon loss.
  • Below 4 t/h with intermittent duty and cheap labour, a fixed grate still makes commercial sense.
  • For coal with more than 25% ash or a low ash fusion temperature, choose a chain grate with water-cooled side walls and a longer burnout zone.
  • If the coal supply is inconsistent, chain grate tolerates variation better, but only when fines are screened out.
  • Never select the grate before the coal analysis is fixed in writing. Ash fusion temperature and volatile matter decide more than the capacity table.

Our engineers specify the grate, furnace volume and air distribution as one package. A grate that is correct on paper can still fail if the furnace is too short for the volatile release of the coal in question.